Specifications
SKU: 11765232
Parameter | Description | Value |
---|---|---|
Part Number | Full part number | BTB12-600BWRG |
Type | Device type | Triac |
Mounting Type | Surface mount or through-hole | Through-Hole |
Package Type | Package style | TO-220AC |
Maximum RMS Voltage (VDRM) | Maximum repetitive peak off-state voltage | 600 V |
Maximum RMS Current (IT(RMS)) | Maximum RMS on-state current | 12 A |
Maximum Non-Repetitive Surge Current (ITSM) | Maximum non-repetitive surge current (8.3 ms, sin 1/2 wave) | 500 A |
Minimum Holding Current (IH) | Minimum holding current | 10 mA |
Gate Trigger Current (IGT) | Gate trigger current | 10 mA (max) |
Dissipation (PT) | Total power dissipation (at TC = 75°C) | 120 W |
Operating Temperature Range (TJ) | Junction temperature range | -40°C to +125°C |
Storage Temperature Range (TSTG) | Storage temperature range | -65°C to +150°C |
Insulation Resistance (RDS) | Insulation resistance at 25°C | >100 MΩ |
Isolation Voltage (VISO) | Isolation voltage (50/60 Hz, 1 minute) | 2500 VAC |
Instructions for Use
Mounting:
- Ensure the device is mounted with proper heat sinking to maintain junction temperature within the specified range.
- Use a thermal compound between the device and the heat sink for optimal thermal performance.
Electrical Connections:
- Connect the main terminals (MT1 and MT2) to the load and power supply.
- Connect the gate terminal (G) to the control circuit.
- Ensure all connections are secure and free from shorts or loose contacts.
Triggering:
- Apply a sufficient gate current (IGT) to turn on the triac.
- The gate current should be within the specified range to ensure reliable operation.
Overcurrent Protection:
- Implement overcurrent protection to prevent damage from excessive currents.
- Use a fuse or circuit breaker rated appropriately for the application.
Surge Handling:
- The device can handle non-repetitive surge currents up to 500 A for short durations (8.3 ms, sin 1/2 wave).
- Ensure that any surge conditions do not exceed this limit.
Temperature Management:
- Monitor the junction temperature to ensure it remains within the operating range.
- Use appropriate cooling methods if necessary to maintain temperature control.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range.
- Avoid exposure to extreme temperatures or humidity.
Handling:
- Handle the device with care to avoid mechanical damage.
- Use static-protective measures to prevent electrostatic discharge (ESD) damage.
By following these parameters and instructions, you can ensure the reliable and safe operation of the BTB12-600BWRG triac in your application.