Share:


BTB12-600BWRG

Specifications

SKU: 11765232

BUY BTB12-600BWRG https://www.utsource.net/itm/p/11765232.html

Parameter Description Value
Part Number Full part number BTB12-600BWRG
Type Device type Triac
Mounting Type Surface mount or through-hole Through-Hole
Package Type Package style TO-220AC
Maximum RMS Voltage (VDRM) Maximum repetitive peak off-state voltage 600 V
Maximum RMS Current (IT(RMS)) Maximum RMS on-state current 12 A
Maximum Non-Repetitive Surge Current (ITSM) Maximum non-repetitive surge current (8.3 ms, sin 1/2 wave) 500 A
Minimum Holding Current (IH) Minimum holding current 10 mA
Gate Trigger Current (IGT) Gate trigger current 10 mA (max)
Dissipation (PT) Total power dissipation (at TC = 75°C) 120 W
Operating Temperature Range (TJ) Junction temperature range -40°C to +125°C
Storage Temperature Range (TSTG) Storage temperature range -65°C to +150°C
Insulation Resistance (RDS) Insulation resistance at 25°C >100 MΩ
Isolation Voltage (VISO) Isolation voltage (50/60 Hz, 1 minute) 2500 VAC

Instructions for Use

  1. Mounting:

    • Ensure the device is mounted with proper heat sinking to maintain junction temperature within the specified range.
    • Use a thermal compound between the device and the heat sink for optimal thermal performance.
  2. Electrical Connections:

    • Connect the main terminals (MT1 and MT2) to the load and power supply.
    • Connect the gate terminal (G) to the control circuit.
    • Ensure all connections are secure and free from shorts or loose contacts.
  3. Triggering:

    • Apply a sufficient gate current (IGT) to turn on the triac.
    • The gate current should be within the specified range to ensure reliable operation.
  4. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage from excessive currents.
    • Use a fuse or circuit breaker rated appropriately for the application.
  5. Surge Handling:

    • The device can handle non-repetitive surge currents up to 500 A for short durations (8.3 ms, sin 1/2 wave).
    • Ensure that any surge conditions do not exceed this limit.
  6. Temperature Management:

    • Monitor the junction temperature to ensure it remains within the operating range.
    • Use appropriate cooling methods if necessary to maintain temperature control.
  7. Storage:

    • Store the device in a dry, cool place within the specified storage temperature range.
    • Avoid exposure to extreme temperatures or humidity.
  8. Handling:

    • Handle the device with care to avoid mechanical damage.
    • Use static-protective measures to prevent electrostatic discharge (ESD) damage.

By following these parameters and instructions, you can ensure the reliable and safe operation of the BTB12-600BWRG triac in your application.

(For reference only)

 Inquiry - BTB12-600BWRG