Specifications
SKU: 11768369
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | Operating | 4.5 | 5.0 | 5.5 | V |
Standby Current | Icc(s) | Vcc = 5V, CS = Vcc, OE = Vcc | - | 1 | 2 | μA |
Active Current | Icc(a) | Vcc = 5V, Continuous Read | - | 30 | 50 | mA |
Access Time | tAA | Vcc = 5V, CL = 15pF | - | 70 | - | ns |
Output High Level | VOH | IOL = -0.4mA | 2.4 | - | Vcc-0.5 | V |
Output Low Level | VOL | IOH = 0.4mA | 0 | - | 0.5 | V |
Input Low Voltage | VIL | - | 0 | - | 0.8 | V |
Input High Voltage | VIH | - | 2.0 | - | Vcc | V |
Storage Temperature | Tstg | - | -65 | - | 150 | °C |
Operating Temperature | Topr | - | 0 | - | 70 | °C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 4.5V to 5.5V.
- The device has a low standby current, making it suitable for battery-operated systems.
Signal Levels:
- The input signals (CS, OE) should be within the specified input voltage levels (VIL and VIH).
- The output signals (VOH and VOL) will be within the specified levels when driving the specified currents.
Timing:
- The access time (tAA) is 70ns under typical conditions. Ensure that the system clock or timing controller can meet this requirement.
Temperature:
- The operating temperature range is 0°C to 70°C.
- The storage temperature range is -65°C to 150°C. Store the device in a suitable environment to avoid damage.
Handling:
- Handle the device with care to avoid static discharge (ESD). Use proper ESD protection measures during handling and installation.
Mounting:
- Follow the recommended PCB layout and soldering guidelines to ensure reliable operation and prevent damage to the device.
Testing:
- After mounting, verify the power supply and signal levels to ensure the device is functioning correctly. Perform functional tests as per the application requirements.
Inquiry - HY62256ALP-70