Specifications
SKU: 11772482
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDSS | - | 500 | - | V | |
Gate-Source Voltage | VGSS | -15 | - | 15 | V | |
Continuous Drain Current | ID | - | 94 | - | A | @ TC = 25°C |
Pulse Drain Current | ID(p) | - | 188 | - | A | @ TC = 25°C, tp = 10 μs, IGS = 10 A |
Power Dissipation | PTOT | - | 300 | - | W | @ TC = 25°C |
Junction Temperature | TJ | - | - | 175 | °C | |
Storage Temperature | TSTG | -55 | - | 150 | °C | |
Thermal Resistance, Junction to Case | RθJC | - | 0.38 | - | °C/W | |
Input Capacitance | Ciss | - | 1500 | - | pF | @ VDS = 400 V, f = 1 MHz |
Output Capacitance | Coss | - | 250 | - | pF | @ VDS = 400 V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 150 | - | pF | @ VDS = 400 V, f = 1 MHz |
Gate Charge | Qg | - | 110 | - | nC | @ VGS = 15 V, ID = 94 A |
Turn-On Delay Time | td(on) | - | 20 | - | ns | @ VGS = 15 V, ID = 94 A |
Rise Time | tr | - | 25 | - | ns | @ VGS = 15 V, ID = 94 A |
Turn-Off Delay Time | td(off) | - | 25 | - | ns | @ VGS = 15 V, ID = 94 A |
Fall Time | tf | - | 30 | - | ns | @ VGS = 15 V, ID = 94 A |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical stress.
- Mount the device on a heatsink to manage thermal resistance effectively.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Use short and wide leads to minimize inductance and improve performance.
Thermal Management:
- Ensure adequate cooling to keep the junction temperature within the specified limits.
- Use thermal grease or a thermal pad between the device and the heatsink for better heat transfer.
Gate Drive:
- Apply the correct gate-source voltage (VGS) to ensure proper turn-on and turn-off.
- Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
Overvoltage Protection:
- Implement overvoltage protection circuits to prevent damage from voltage spikes.
- Consider using snubber circuits to dampen voltage transients.
Storage and Operating Conditions:
- Store the device in a dry and cool environment to prevent moisture damage.
- Operate the device within the specified temperature range to ensure reliable performance.
Testing:
- Perform initial testing at low power levels to verify correct operation.
- Gradually increase the load to the rated values while monitoring temperature and performance.
By following these guidelines, you can ensure optimal performance and reliability of the IXFK94N50P2 MOSFET.
(For reference only)Inquiry - IXFK94N50P2 IXYS TO264 94A/500V MOS