IXFK94N50P2 IXYS TO264 94A/500V MOS

Specifications

SKU: 11772482

BUY IXFK94N50P2 IXYS TO264 94A/500V MOS https://www.utsource.net/itm/p/11772482.html

Parameter Symbol Min Typical Max Unit Notes
Drain-Source Voltage VDSS - 500 - V
Gate-Source Voltage VGSS -15 - 15 V
Continuous Drain Current ID - 94 - A @ TC = 25°C
Pulse Drain Current ID(p) - 188 - A @ TC = 25°C, tp = 10 μs, IGS = 10 A
Power Dissipation PTOT - 300 - W @ TC = 25°C
Junction Temperature TJ - - 175 °C
Storage Temperature TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RθJC - 0.38 - °C/W
Input Capacitance Ciss - 1500 - pF @ VDS = 400 V, f = 1 MHz
Output Capacitance Coss - 250 - pF @ VDS = 400 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 150 - pF @ VDS = 400 V, f = 1 MHz
Gate Charge Qg - 110 - nC @ VGS = 15 V, ID = 94 A
Turn-On Delay Time td(on) - 20 - ns @ VGS = 15 V, ID = 94 A
Rise Time tr - 25 - ns @ VGS = 15 V, ID = 94 A
Turn-Off Delay Time td(off) - 25 - ns @ VGS = 15 V, ID = 94 A
Fall Time tf - 30 - ns @ VGS = 15 V, ID = 94 A

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is handled with care to avoid mechanical stress.
    • Mount the device on a heatsink to manage thermal resistance effectively.
  2. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals correctly.
    • Use short and wide leads to minimize inductance and improve performance.
  3. Thermal Management:

    • Ensure adequate cooling to keep the junction temperature within the specified limits.
    • Use thermal grease or a thermal pad between the device and the heatsink for better heat transfer.
  4. Gate Drive:

    • Apply the correct gate-source voltage (VGS) to ensure proper turn-on and turn-off.
    • Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
  5. Overvoltage Protection:

    • Implement overvoltage protection circuits to prevent damage from voltage spikes.
    • Consider using snubber circuits to dampen voltage transients.
  6. Storage and Operating Conditions:

    • Store the device in a dry and cool environment to prevent moisture damage.
    • Operate the device within the specified temperature range to ensure reliable performance.
  7. Testing:

    • Perform initial testing at low power levels to verify correct operation.
    • Gradually increase the load to the rated values while monitoring temperature and performance.

By following these guidelines, you can ensure optimal performance and reliability of the IXFK94N50P2 MOSFET.