Specifications
SKU: 11773269
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Rated On-State Current | IT(RMS) | - | 8 | - | A | |
Peak On-State Current | ITSM | - | 50 | - | A | 10 ms, non-repetitive |
On-State Voltage | VT | - | 1.4 | - | V | @ IT = 8 A, Tj = 25°C |
Holding Current | IH | - | 10 | - | mA | |
Gate Trigger Current | IG(T) | - | 10 | - | mA | |
Gate Trigger Voltage | VG(T) | - | 2.5 | - | V | |
Maximum Off-State Voltage | VDRM | - | 400 | - | V | |
Power Dissipation | PD | - | 75 | - | W | @ Tc = 70°C |
Junction Temperature | Tj | -40 | - | 125 | °C | |
Storage Temperature | Tstg | -40 | - | 125 | °C |
Instructions for Use:
Mounting:
- Ensure the BT131-800D is mounted on a heatsink to manage heat dissipation effectively, especially when operating at high currents.
- Use thermal compound between the device and the heatsink to improve thermal conductivity.
Current Handling:
- Do not exceed the rated on-state current (8 A RMS) or peak on-state current (50 A for 10 ms, non-repetitive).
- Ensure the holding current (10 mA) is maintained to keep the device in the on state.
Voltage Considerations:
- The maximum off-state voltage (400 V) should not be exceeded to prevent damage to the device.
- The on-state voltage (1.4 V) should be considered in power loss calculations.
Gate Drive:
- Apply the gate trigger current (10 mA) and gate trigger voltage (2.5 V) as specified to ensure reliable turn-on.
- Avoid applying excessive gate voltage to prevent damage.
Temperature Management:
- Monitor the junction temperature (Tj) to ensure it stays within the range of -40°C to 125°C.
- Store the device within the storage temperature range (-40°C to 125°C).
Handling and Storage:
- Handle the device with care to avoid mechanical stress or damage.
- Store in a dry, cool place to prevent moisture-related issues.
Testing:
- Before final assembly, test the device under controlled conditions to ensure it meets the required specifications.
Safety:
- Always follow safety guidelines when working with electrical components to prevent injury or damage.
By adhering to these parameters and instructions, you can ensure optimal performance and longevity of the BT131-800D triac.
(For reference only)Inquiry - BT131-800D