Share:


AM27C512-90DC

Specifications

SKU: 11774540

BUY AM27C512-90DC https://www.utsource.net/itm/p/11774540.html

Parameter Symbol Min Typ Max Unit Notes
Supply Voltage Vcc 4.75 5 5.25 V
Standby Current ICCS - 5 10 μA
Active Current ICCA 10 20 30 mA
Access Time tAA 90 - - ns
Output High Voltage VOH 2.4 - Vcc-0.5 V
Output Low Voltage VOL 0 - 0.5 V
Input High Voltage VIH 2.0 - Vcc-0.5 V
Input Low Voltage VIL 0 - 0.8 V
Storage Temperature Tstg -65 - 150 °C
Operating Temperature Topr 0 - 70 °C
Data Retention Time tret - - 20 years

Instructions for Using AM27C512-90DC

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the specified range of 4.75V to 5.25V.
    • Connect the ground (GND) pin to a stable 0V reference.
  2. Pin Configuration:

    • Refer to the datasheet for the specific pinout diagram.
    • Connect the address lines (A0-A18) to the appropriate address bus.
    • Connect the data lines (D0-D7) to the data bus.
    • Connect the control signals (OE, CE, WE) as required by your system.
  3. Operation Modes:

    • Read Operation:
      • Set the chip enable (CE) and output enable (OE) pins low.
      • Apply the desired address to the address lines.
      • The data at the specified address will appear on the data lines after the access time (tAA).
    • Write Operation:
      • Set the chip enable (CE) and write enable (WE) pins low.
      • Apply the desired address to the address lines.
      • Apply the data to be written to the data lines.
      • The data will be written to the specified address after the access time (tAA).
  4. Temperature Considerations:

    • Ensure the operating temperature (Topr) does not exceed 70°C.
    • Store the device within the storage temperature range (-65°C to 150°C).
  5. Data Retention:

    • The device guarantees data retention for up to 20 years under normal operating conditions.
  6. Handling Precautions:

    • Handle the device with care to avoid static discharge, which can damage the internal circuitry.
    • Use proper anti-static precautions when handling and storing the device.
  7. Testing and Verification:

    • After installation, verify the functionality of the device using a known good test pattern or diagnostic tool.

For detailed information and specific application notes, refer to the full datasheet provided by the manufacturer.

(For reference only)

 Inquiry - AM27C512-90DC