Parameter Symbol Min Typical Max Unit Conditions
Drain-Source Voltage VDS - 650 - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - 11 - A TC = 25°C
Pulse Drain Current IDpeak - 33 - A tp = 10 μs, IGT = 4 A
Total Power Dissipation PTOT - 190 - W TC = 25°C
Junction Temperature TJ - - 150 °C
Storage Temperature Range TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RθJC - 0.8 - °C/W
Input Capacitance Ciss - 1700 - pF VDS = 400 V, f = 1 MHz
Output Capacitance Coss - 110 - pF VDS = 400 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 50 - pF VDS = 400 V, f = 1 MHz
Turn-On Delay Time td(on) - 45 - ns VGS = 15 V, ID = 11 A
Rise Time tr - 45 - ns VGS = 15 V, ID = 11 A
Turn-Off Delay Time td(off) - 45 - ns VGS = -15 V, ID = 11 A
Fall Time tf - 45 - ns VGS = -15 V, ID = 11 A

Instructions for Use:

  1. Handling Precautions:

    • Handle the MDF11N65B with care to avoid damage to the leads and body.
    • Use ESD (Electrostatic Discharge) protection when handling to prevent damage from static electricity.
  2. Mounting:

    • Ensure proper heat sinking to manage the thermal resistance and maintain the junction temperature within safe limits.
    • Follow recommended PCB layout guidelines to minimize parasitic inductances and ensure reliable operation.
  3. Biasing:

    • Apply the gate-source voltage (VGS) within the specified range to avoid damage.
    • Use a gate resistor to control the switching speed and reduce EMI (Electromagnetic Interference).
  4. Operation:

    • Operate the device within the specified drain-source voltage (VDS) and continuous drain current (ID) ratings.
    • Monitor the junction temperature (TJ) to ensure it does not exceed the maximum rating.
  5. Storage:

    • Store the device in a dry, cool environment within the specified storage temperature range (TSTG).
  6. Testing:

    • Use appropriate test equipment and methods to verify the performance parameters.
    • Ensure that all testing is performed under controlled conditions to avoid damage to the device.
  7. Safety:

    • Follow all relevant safety guidelines and regulations when using the MDF11N65B.
    • Use protective equipment as necessary to prevent injury.
(For reference only)