Specifications
SKU: 11777086
Parameter | Symbol | Min | Typical | Max | Unit | Condition |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | 500 | - | V | - |
Gate-Source Voltage | VGS | -20 | - | 20 | V | - |
Continuous Drain Current | ID | - | 18 | - | A | TC = 25°C |
Pulse Drain Current | ID(p) | - | 60 | - | A | tp = 10 ms, IG = 10 A, TC = 25°C |
Gate Charge | QG | - | 130 | - | nC | - |
Input Capacitance | Ciss | - | 1900 | - | pF | VDS = 25 V, f = 1 MHz |
Output Capacitance | Coss | - | 170 | - | pF | VDS = 25 V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 1730 | - | pF | VDS = 25 V, f = 1 MHz |
Total Gate Charge | QGT | - | 130 | - | nC | VGS = 15 V, ID = 10 A |
Threshold Gate Voltage | VGS(th) | 2.0 | 4.0 | 6.0 | V | ID = 250 μA, TJ = 25°C |
On-State Resistance | RDS(on) | - | 0.35 | - | Ω | VGS = 10 V, ID = 10 A, TJ = 25°C |
Power Dissipation | PT | - | 150 | - | W | TC = 25°C |
Junction Temperature | TJ | - | - | 150 | °C | - |
Storage Temperature | Tstg | -55 | - | 150 | °C | - |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical damage.
- Use appropriate thermal management techniques, such as heatsinks, to maintain the junction temperature within safe limits.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly to avoid damage.
- Ensure that the gate-source voltage (VGS) does not exceed the maximum rating to prevent gate oxide breakdown.
Thermal Management:
- The device should be mounted on a suitable heatsink to dissipate the heat generated during operation.
- Monitor the junction temperature (TJ) to ensure it does not exceed 150°C.
Pulse Operation:
- For pulse operation, ensure that the pulse duration (tp) and current (ID(p)) do not exceed the specified limits to avoid thermal runaway.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range (-55°C to 150°C).
Testing:
- When testing the device, use the recommended test conditions to obtain accurate results.
- Ensure that the test equipment is properly calibrated and grounded to avoid damage to the device.
Safety Precautions:
- Always follow safety guidelines when handling high-voltage and high-current circuits.
- Use appropriate personal protective equipment (PPE) when necessary.
By following these instructions, you can ensure reliable and efficient operation of the IRFP140NPBF IRFP140 TO-247 MOSFET.
(For reference only)Inquiry - IRFP140NPBF IRFP140 TO-247