Share:


CPC1907B

Specifications

SKU: 11778141

BUY CPC1907B https://www.utsource.net/itm/p/11778141.html

Parameter Description Value Unit
Part Number Component Identifier CPC1907B -
Type Component Type Phototriac -
VDRM Repetitive Peak Off-State Voltage 600 V
IT(RMS) RMS On-State Current 0.75 A
ITSM Non-Repetitive Peak On-State Current 10 A
VT Gate Trigger Voltage 1.3 to 2.0 V
IT Gate Trigger Current 5 to 20 mA
Power Dissipation Maximum Power Dissipation 125 mW
Operating Temperature Ambient Temperature Range -40 to 85 °C
Isolation Voltage Electrical Isolation Voltage 5000 VRMS
Storage Temperature Storage Temperature Range -40 to 125 °C
Package Package Type DIP-4 -

Instructions for Use:

  1. Mounting:

    • Ensure the CPC1907B is mounted on a PCB with adequate spacing to prevent short circuits.
    • Use appropriate soldering techniques to avoid overheating.
  2. Electrical Connections:

    • Connect the phototriac in series with the load and the AC supply.
    • Ensure the correct polarity is observed when connecting the gate and the main terminals.
  3. Triggering:

    • Apply a trigger current (IT) to the gate terminal to turn the phototriac on.
    • The trigger voltage (VT) should be within the specified range to ensure reliable operation.
  4. Heat Management:

    • Ensure that the operating temperature does not exceed the maximum ambient temperature of 85°C.
    • Consider using a heatsink if the device will be operating at high currents or in high-temperature environments.
  5. Isolation:

    • The CPC1907B provides electrical isolation up to 5000 VRMS. Ensure that this isolation is maintained to prevent electrical hazards.
  6. Storage:

    • Store the device in a dry environment within the storage temperature range of -40 to 125°C to maintain its performance characteristics.
  7. Handling:

    • Handle the device with care to avoid mechanical damage.
    • Use ESD (Electrostatic Discharge) protection when handling to prevent damage from static electricity.
  8. Testing:

    • Before final assembly, test the phototriac in a controlled environment to ensure it meets the required specifications.
  9. Compliance:

    • Ensure that the use of the CPC1907B complies with all relevant safety and regulatory standards.
(For reference only)

 Inquiry - CPC1907B