Specifications
SKU: 12399518
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | - | 30 | V | |
Operating Current | Icc | - | 12 | 25 | mA | |
Maximum Output Current | Iout | - | - | 2 | A | Per channel |
Maximum Power Dissipation | Pd | - | - | 100 | W | |
Operating Temperature | Toper | -40 | - | 150 | °C | |
Storage Temperature | Tstg | -40 | - | 150 | °C | |
Thermal Resistance (θja) | θja | - | 50 | - | °C/W | |
Input Voltage Range | Vin | 0 | - | 5 | V | |
Maximum Gate Voltage | Vgs | -20 | - | 20 | V | |
Maximum Drain Voltage | Vds | - | - | 60 | V | |
Rise Time | tr | - | 100 | - | ns | |
Fall Time | tf | - | 100 | - | ns | |
Propagation Delay | tpd | - | 100 | - | ns |
Instructions for Using the L6387ED
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 4.5V to 30V.
- The operating current (Icc) can vary between 12mA and 25mA depending on the load.
Output Configuration:
- The maximum output current per channel is 2A. Ensure that the load does not exceed this limit to avoid damage.
- The maximum power dissipation is 100W. Use appropriate heat sinks or cooling methods if operating at high power levels.
Temperature Considerations:
- The device can operate within a temperature range of -40°C to 150°C.
- Store the device in an environment with temperatures between -40°C and 150°C.
Input Signals:
- The input voltage range (Vin) should be between 0V and 5V.
- Ensure the input signals are within this range to prevent damage to the device.
Gate and Drain Voltages:
- The maximum gate voltage (Vgs) should not exceed ±20V.
- The maximum drain voltage (Vds) should not exceed 60V.
Timing Parameters:
- The rise time (tr) and fall time (tf) are both approximately 100ns.
- The propagation delay (tpd) is also around 100ns. These parameters are important for ensuring proper timing in your circuit.
Thermal Management:
- The thermal resistance (θja) is 50°C/W. Use appropriate heatsinks or cooling solutions to manage heat, especially under high-power conditions.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store the device in a dry, cool place to prevent moisture damage.
By following these guidelines, you can ensure optimal performance and longevity of the L6387ED.