Specifications
SKU: 12401287
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | 650 | - | V | - |
Gate-Source Voltage | VGS | -20 | - | 20 | V | - |
Continuous Drain Current | ID | - | 60 | - | A | TC = 25°C |
Power Dissipation | PTOT | - | - | 370 | W | TC = 25°C |
Junction Temperature | TJ | - | - | 175 | °C | - |
Storage Temperature | TSTG | -55 | - | 150 | °C | - |
Total Gate Charge | QG | - | 140 | - | nC | VDS = 400V, ID = 20A, VGS = 15V |
Input Capacitance | Ciss | - | 3500 | - | pF | VDS = 400V, f = 1 MHz |
Output Capacitance | Coss | - | 1100 | - | pF | VDS = 400V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 700 | - | pF | VDS = 400V, f = 1 MHz |
On-State Resistance | RDS(on) | - | 0.85 | - | Ω | VGS = 10V, ID = 60A, TJ = 25°C |
Turn-On Delay Time | td(on) | - | 40 | - | ns | VDS = 400V, ID = 20A, VGS = 15V, RG = 2Ω |
Rise Time | tr | - | 40 | - | ns | VDS = 400V, ID = 20A, VGS = 15V, RG = 2Ω |
Turn-Off Delay Time | td(off) | - | 40 | - | ns | VDS = 400V, ID = 20A, VGS = 15V, RG = 2Ω |
Fall Time | tf | - | 50 | - | ns | VDS = 400V, ID = 20A, VGS = 15V, RG = 2Ω |
Instructions:
Handling and Storage:
- Store the device in a dry, cool place.
- Handle with care to avoid damage to the leads and body.
- Use ESD (Electrostatic Discharge) protection when handling the device.
Mounting:
- Ensure proper heat sinking to manage the power dissipation.
- Use recommended PCB layout and mounting techniques to ensure reliable performance.
Operating Conditions:
- Do not exceed the maximum ratings listed in the table.
- Operate within the specified temperature range to avoid thermal damage.
- Ensure adequate cooling for continuous operation at high currents.
Gate Drive:
- Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
- Ensure the gate voltage is within the specified range to prevent overvoltage or undervoltage conditions.
Testing:
- Use appropriate test equipment and procedures to measure parameters.
- Follow safety guidelines to prevent electrical shock and damage to the device.
Applications:
- Suitable for high-frequency switching applications such as SMPS (Switch Mode Power Supplies), motor drives, and inverters.
Inquiry - FGA60N65SMD