Specifications
SKU: 12442444
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 40 | V |
Output Voltage | VOUT | - | 5.0 | - | V |
Output Current | IOUT | - | 600 | - | mA |
Quiescent Current | IQ | - | 2.5 | - | mA |
Dropout Voltage | VDO | - | 0.3 | - | V |
Load Regulation | - | - | 0.2 | - | % |
Line Regulation | - | - | 0.1 | - | % |
Ripple Rejection | - | 70 | - | 80 | dB |
Operating Temperature | TOP | -40 | - | 85 | °C |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Thermal Resistance (θJA) | - | - | 60 | - | °C/W |
Instructions for Use:
Input Voltage:
- Ensure the input voltage is within the range of 4.5V to 40V.
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Voltage:
- The output voltage is fixed at 5.0V. No external components are required for voltage regulation.
Output Current:
- The device can provide up to 600mA of output current. Ensure the load does not exceed this limit to avoid overheating or failure.
Quiescent Current:
- The quiescent current is typically 2.5mA. This is the current consumed by the regulator when there is no load.
Dropout Voltage:
- The dropout voltage is typically 0.3V. Ensure the input voltage is at least 0.3V higher than the output voltage to maintain regulation.
Load Regulation:
- The load regulation is typically 0.2%. This indicates the change in output voltage due to changes in load current.
Line Regulation:
- The line regulation is typically 0.1%. This indicates the change in output voltage due to changes in input voltage.
Ripple Rejection:
- The ripple rejection is between 70dB and 80dB. This measures the ability of the regulator to reject input ripple.
Operating Temperature:
- The operating temperature range is from -40°C to 85°C. Ensure the device operates within this range to avoid performance degradation or failure.
Storage Temperature:
- The storage temperature range is from -65°C to 150°C. Store the device in this range to prevent damage.
Thermal Resistance:
- The thermal resistance (θJA) is typically 60°C/W. Ensure adequate heat dissipation if the device is expected to operate under high power conditions.
Mounting:
- Mount the device on a PCB with proper thermal management. Use a heatsink if necessary to dissipate heat effectively.
Capacitors:
- Use appropriate input and output capacitors to stabilize the circuit and reduce ripple. Refer to the datasheet for recommended capacitor values and types.
Inquiry - SF10A600H