Specifications
SKU: 12529456
Parameter | Symbol | Test Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 1.0A, TA = 25°C | - | 0.45 | 0.75 | V |
Reverse Recovery Time | trr | IF = 1.0A, IR = 0.1A, TJ = 25°C | - | - | 60 | ns |
Peak Reverse Recovery Current | Irm | IF = 1.0A, IR = 0.1A, TJ = 25°C | - | - | 2.0 | A |
Maximum RMS Voltage | VRRM | - | - | - | 40 | V |
Maximum Repetitive Peak Reverse Voltage | VRSM | - | - | - | 40 | V |
Maximum DC Blocking Voltage | VDC | - | - | - | 40 | V |
Average Rectified Output Current (TA = 70°C) | IF(AV) | f = 50/60Hz | - | - | 1.0 | A |
Average Rectified Output Current (TA = 105°C) | IF(AV) | f = 50/60Hz | - | - | 0.8 | A |
Non-Repetitive Peak Surge Current | IFSM | Tj = 25°C, td = 8.3ms, f = 50/60Hz | - | - | 50 | A |
Junction Temperature | TJ | - | - | - | 150 | °C |
Storage Temperature Range | TSTG | - | -55 | - | 150 | °C |
Instructions for Use:
Mounting and Handling:
- Handle the MBRM140T3G with care to avoid mechanical damage.
- Ensure that the device is mounted on a suitable heatsink if high power dissipation is expected.
Electrical Connections:
- Connect the device according to the polarity indicated on the package.
- Ensure that all connections are secure and free from corrosion or oxidation.
Thermal Management:
- The junction temperature should not exceed 150°C to ensure reliable operation.
- Use appropriate thermal management techniques, such as heatsinks or forced air cooling, to maintain the junction temperature within safe limits.
Surge Current:
- The non-repetitive peak surge current (IFSM) should not be exceeded, as it can cause permanent damage to the device.
- Ensure that any surge currents are within the specified limits and do not occur too frequently.
Storage:
- Store the device in a dry, cool place within the storage temperature range of -55°C to 150°C.
- Avoid exposing the device to extreme temperatures or humidity.
Testing:
- When testing the device, ensure that the test conditions match those specified in the parameter table to obtain accurate results.
- Use appropriate test equipment and follow safety guidelines to prevent damage to the device or injury.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for the intended application.
Inquiry - MBRM140T3G