Specifications
SKU: 12536051
Below is the parameter table and instructions for the G4PC40UD optocoupler:
Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Current (IF) | IF | - | 15 | 20 | mA | Continuous |
Peak Forward Current (IFM) | IFM | - | - | 50 | mA | Pulse Width ≤ 1 ms, Duty Cycle ≤ 1% |
Forward Voltage (VF) | VF | 1.0 | 1.2 | 1.6 | V | IF = 20 mA |
Reverse Voltage (VR) | VR | - | - | 5 | V | |
Output Collector-Emitter Voltage (VCEO) | VCEO | - | - | 40 | V | IC = 50 mA |
Output Collector Current (IC) | IC | - | 50 | 100 | mA | VCE = 5 V |
CTR (Current Transfer Ratio) | CTR | 50 | 100 | 200 | % | IF = 5 mA, IC = 1 mA |
Rise Time (tr) | tr | - | 3 | 5 | μs | RL = 1 kΩ, IF = 5 mA, IC = 5 mA |
Fall Time (tf) | tf | - | 3 | 5 | μs | RL = 1 kΩ, IF = 5 mA, IC = 5 mA |
Storage Temperature Range | Tstg | -40 | - | 105 | °C | |
Operating Temperature Range | Topr | -40 | - | 85 | °C |
Instructions
Handling and Storage:
- Store the device in a dry place to avoid moisture damage.
- Handle with care to avoid mechanical stress on the leads.
Forward Current (IF):
- Do not exceed the maximum forward current of 20 mA continuously.
- For pulse applications, ensure that the peak forward current does not exceed 50 mA with a pulse width of ≤ 1 ms and a duty cycle of ≤ 1%.
Reverse Voltage (VR):
- The device can withstand a reverse voltage of up to 5 V. Exceeding this may cause damage.
Output Collector-Emitter Voltage (VCEO):
- Ensure that the collector-emitter voltage does not exceed 40 V when the collector current is 50 mA.
Output Collector Current (IC):
- The typical collector current is 50 mA, but it can go up to 100 mA. Ensure that the load resistance is appropriate to limit the current within these limits.
Current Transfer Ratio (CTR):
- The CTR ranges from 50% to 200% at IF = 5 mA and IC = 1 mA. This indicates the efficiency of current transfer from the input to the output side.
Rise and Fall Times (tr, tf):
- The rise and fall times are typically 3 μs and can be as high as 5 μs. These values are measured with a load resistance of 1 kΩ and IF = 5 mA, IC = 5 mA.
Temperature Ranges:
- The storage temperature range is -40°C to 105°C.
- The operating temperature range is -40°C to 85°C. Ensure that the device operates within these limits to avoid thermal damage.
Mounting:
- Use proper soldering techniques to avoid thermal shock and mechanical stress.
- Ensure good thermal management if the device will operate at high currents or temperatures.
Testing:
- Before integrating the device into a circuit, test its parameters to ensure they meet the specified values.
By following these instructions and adhering to the parameter specifications, you can ensure reliable operation of the G4PC40UD optocoupler in your application.
(For reference only)Inquiry - G4PC40UD