Parameter Description Min Typ Max Unit
Supply Voltage (VDD) Operating voltage range 1.7 - 3.6 V
Standby Current Current consumption in standby mode - 0.5 - μA
Active Current Current consumption in active mode - 20 - mA
Clock Frequency Maximum clock frequency - 50 - MHz
Operating Temperature Temperature range for operation -40 - 85 °C
Storage Temperature Temperature range for storage -55 - 125 °C
Input Voltage Range Range for digital input signals 0 - VDD V
Output Voltage Range Range for digital output signals 0 - VDD V
I/O Pin Count Number of I/O pins - 48 - -
Package Type Type of package - QFN-48 - -

Instructions for Using MB86S72

  1. Power Supply:

    • Ensure that the supply voltage (VDD) is within the range of 1.7V to 3.6V.
    • Use a stable power source to avoid voltage fluctuations.
  2. Current Consumption:

    • In standby mode, the current consumption is typically 0.5 μA.
    • In active mode, the current consumption is typically 20 mA.
  3. Clock Configuration:

    • The maximum clock frequency is 50 MHz. Ensure that the clock signal is stable and within this range.
  4. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -55°C to 125°C. Store the device in a dry and cool place.
  5. Signal Levels:

    • Digital input signals should be within the range of 0V to VDD.
    • Digital output signals will also be within the range of 0V to VDD.
  6. Pin Configuration:

    • The MB86S72 has 48 I/O pins. Refer to the datasheet for the specific pinout and their functions.
  7. Package Handling:

    • The device is available in a QFN-48 package. Handle the package with care to avoid damage to the pins and the device.
  8. Programming:

    • Follow the programming guidelines provided in the datasheet for configuring and using the MB86S72.
    • Use appropriate development tools and software for programming and debugging.
  9. Testing:

    • After assembly, perform initial testing to ensure all connections are correct and the device is functioning as expected.
    • Conduct functional tests under different operating conditions to verify performance.
  10. Safety:

    • Ensure proper grounding and use anti-static precautions when handling the device to prevent electrostatic discharge (ESD) damage.
    • Follow all safety guidelines and regulations applicable to your application.