Share:


FQP27P06(UMW)

Specifications

SKU: 12593486

BUY FQP27P06(UMW) https://www.utsource.net/itm/p/12593486.html

Parameter Symbol Conditions Min Typical Max Unit
Drain-Source Voltage VDS Continuous - 60 - V
Gate-Source Voltage VGS Continuous -15 0 15 V
Continuous Drain Current ID TC = 25°C - 27 - A
TC = 70°C - 21 - A
TC = 100°C - 18 - A
Pulse Drain Current ID(pulse) tp = 10 ms, TC = 25°C - 54 - A
Gate Charge QG VGS = 10V - 30 - nC
Input Capacitance Ciss VDS = 10V, f = 1 MHz - 940 - pF
Output Capacitance Coss VDS = 10V, f = 1 MHz - 320 - pF
Total Gate-to-Source Capacitance Crss VDS = 10V, f = 1 MHz - 120 - pF
Threshold Gate Voltage VGS(th) ID = 250 μA 1.0 2.0 4.0 V
On-State Resistance RDS(on) VGS = 10V, ID = 27A - 0.022 - Ω
Power Dissipation PD TC = 25°C - 140 - W
Junction Temperature TJ Operating Range -40 - 150 °C
Storage Temperature Tstg - -65 - 150 °C

Instructions for Use:

  1. Handling Precautions:

    • The FQP27P06 is sensitive to electrostatic discharge (ESD). Use proper ESD protection when handling.
    • Avoid exceeding the maximum ratings listed in the table to prevent damage to the device.
  2. Mounting:

    • Ensure good thermal management by using appropriate heatsinks if operating at high currents or power dissipation.
    • Follow recommended PCB layout guidelines to minimize parasitic inductances and ensure stable operation.
  3. Biasing:

    • Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
    • Use a gate resistor to limit the gate current and protect the gate from overvoltage spikes.
  4. Operation:

    • Ensure the drain-source voltage (VDS) does not exceed 60V to prevent breakdown.
    • Monitor the junction temperature (TJ) to stay within the safe operating range, especially during high-power applications.
  5. Testing:

    • When testing the device, use the typical values provided as a reference but always verify the actual performance under your specific application conditions.
  6. Storage:

    • Store the device in a dry, cool place within the specified storage temperature range to maintain its reliability.

For more detailed information, refer to the datasheet provided by the manufacturer.

(For reference only)

 Inquiry - FQP27P06(UMW)