Specifications
SKU: 12593486
Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | Continuous | - | 60 | - | V |
Gate-Source Voltage | VGS | Continuous | -15 | 0 | 15 | V |
Continuous Drain Current | ID | TC = 25°C | - | 27 | - | A |
TC = 70°C | - | 21 | - | A | ||
TC = 100°C | - | 18 | - | A | ||
Pulse Drain Current | ID(pulse) | tp = 10 ms, TC = 25°C | - | 54 | - | A |
Gate Charge | QG | VGS = 10V | - | 30 | - | nC |
Input Capacitance | Ciss | VDS = 10V, f = 1 MHz | - | 940 | - | pF |
Output Capacitance | Coss | VDS = 10V, f = 1 MHz | - | 320 | - | pF |
Total Gate-to-Source Capacitance | Crss | VDS = 10V, f = 1 MHz | - | 120 | - | pF |
Threshold Gate Voltage | VGS(th) | ID = 250 μA | 1.0 | 2.0 | 4.0 | V |
On-State Resistance | RDS(on) | VGS = 10V, ID = 27A | - | 0.022 | - | Ω |
Power Dissipation | PD | TC = 25°C | - | 140 | - | W |
Junction Temperature | TJ | Operating Range | -40 | - | 150 | °C |
Storage Temperature | Tstg | - | -65 | - | 150 | °C |
Instructions for Use:
Handling Precautions:
- The FQP27P06 is sensitive to electrostatic discharge (ESD). Use proper ESD protection when handling.
- Avoid exceeding the maximum ratings listed in the table to prevent damage to the device.
Mounting:
- Ensure good thermal management by using appropriate heatsinks if operating at high currents or power dissipation.
- Follow recommended PCB layout guidelines to minimize parasitic inductances and ensure stable operation.
Biasing:
- Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
- Use a gate resistor to limit the gate current and protect the gate from overvoltage spikes.
Operation:
- Ensure the drain-source voltage (VDS) does not exceed 60V to prevent breakdown.
- Monitor the junction temperature (TJ) to stay within the safe operating range, especially during high-power applications.
Testing:
- When testing the device, use the typical values provided as a reference but always verify the actual performance under your specific application conditions.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range to maintain its reliability.
For more detailed information, refer to the datasheet provided by the manufacturer.
(For reference only)Inquiry - FQP27P06(UMW)