JW2SN-DC24V

Specifications

SKU: 12594856

BUY JW2SN-DC24V https://www.utsource.net/itm/p/12594856.html

Below is the parameter table and instructions for the JW2SN-DC24V.

Parameter Table

Parameter Value
Model Number JW2SN-DC24V
Input Voltage DC 24V
Operating Current 100mA (Max)
Output Type Normally Open (NO)
Contact Rating 5A @ 24V DC
Switching Capacity 120W (Max)
Response Time < 10ms
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Humidity Range 5% to 95% RH (Non-condensing)
Protection Reverse Polarity Protection
Mounting Panel Mount
Dimensions 30mm x 20mm x 15mm
Weight 30g
Certifications CE, RoHS

Instructions

  1. Installation:

    • Ensure that the input voltage is DC 24V.
    • Mount the JW2SN-DC24V on a suitable panel using the provided mounting screws.
    • Connect the input wires to the terminal block labeled "IN" and the output wires to the terminal block labeled "OUT."
  2. Wiring:

    • Input Wiring:
      • Connect the positive terminal of the power supply to the "+" terminal.
      • Connect the negative terminal of the power supply to the "-" terminal.
    • Output Wiring:
      • Connect the load to the "COM" and "NO" terminals.
      • The "COM" terminal is the common terminal.
      • The "NO" terminal is the normally open terminal.
  3. Operation:

    • When the sensor detects the target, the relay will switch from the normally open (NO) state to the closed state, allowing current to flow through the load.
    • The response time is less than 10ms, ensuring quick and reliable operation.
  4. Maintenance:

    • Regularly inspect the connections for any signs of wear or damage.
    • Ensure that the operating environment is within the specified temperature and humidity ranges.
    • Do not exceed the maximum current rating of 5A at 24V DC to avoid damage to the relay.
  5. Troubleshooting:

    • No Output:
      • Check the input voltage and ensure it is DC 24V.
      • Verify that the connections are secure and not loose.
    • Intermittent Operation:
      • Check for any interference or noise in the power supply.
      • Ensure that the load is within the switching capacity of the relay.
  6. Safety Precautions:

    • Always disconnect the power supply before installing or servicing the relay.
    • Use appropriate personal protective equipment (PPE) when handling electrical components.
    • Follow all local electrical codes and regulations.

By following these instructions, you can ensure the safe and efficient operation of the JW2SN-DC24V relay.

(For reference only)