Specifications
SKU: 12598617
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | 5 | 5.5 | V | Operating supply voltage |
Quiescent Current | IQ | - | 10 | - | mA | Current consumption when no load is applied |
Output Current | Iout | - | 100 | - | mA | Maximum continuous output current |
Output Voltage | Vout | - | - | 3.3 | V | Regulated output voltage |
Dropout Voltage | Vdo | - | 0.3 | - | V | Voltage difference between input and output |
Load Regulation | - | - | 0.5 | - | % | Change in output voltage with load |
Line Regulation | - | - | 0.2 | - | % | Change in output voltage with input voltage |
Ripple Rejection | - | 60 | 70 | 80 | dB | Ability to reject input ripple |
Operating Temp. | Toper | -40 | - | 85 | °C | Temperature range for operation |
Storage Temp. | Tstg | -65 | - | 150 | °C | Temperature range for storage |
Instructions:
Supply Voltage (Vcc):
- Ensure the supply voltage is within the range of 4.5V to 5.5V to avoid damage to the device.
Quiescent Current (IQ):
- The quiescent current is typically 10mA. This is the current consumed by the device when no load is applied.
Output Current (Iout):
- The maximum continuous output current is 100mA. Do not exceed this limit to prevent overheating or damage.
Output Voltage (Vout):
- The regulated output voltage is 3.3V. Ensure that the load can operate within this voltage range.
Dropout Voltage (Vdo):
- The dropout voltage is typically 0.3V. This means the input voltage should be at least 0.3V higher than the output voltage to maintain regulation.
Load Regulation:
- The load regulation is 0.5%, indicating that the output voltage will change by 0.5% for changes in load conditions.
Line Regulation:
- The line regulation is 0.2%, indicating that the output voltage will change by 0.2% for changes in input voltage.
Ripple Rejection:
- The ripple rejection is between 60dB and 80dB, which means the device can effectively filter out input voltage ripple.
Operating Temperature (Toper):
- The device is designed to operate within a temperature range of -40°C to 85°C. Ensure the ambient temperature does not exceed these limits.
Storage Temperature (Tstg):
- The device can be stored within a temperature range of -65°C to 150°C. However, ensure it returns to the operating temperature range before use.
Additional Notes:
- Always ensure proper heat dissipation if the device is expected to operate near its maximum output current.
- Use appropriate capacitors for input and output filtering to maintain stability and performance.
- Refer to the datasheet for detailed application circuits and additional information.