Share:


SI4401DDY

Specifications

SKU: 12603634

BUY SI4401DDY https://www.utsource.net/itm/p/12603634.html

Parameter Description Min Typ Max Unit
VCC Supply Voltage 2.1 - 3.6 V
ICC Supply Current (Active Mode) - 2.5 - mA
ICC (Sleep) Supply Current (Sleep Mode) - 0.5 - μA
fOSC Oscillator Frequency 13.56 16 26 MHz
RFREQ Frequency Range 300 - 960 MHz
POUT Output Power -20 0 +10 dBm
RDS Data Rate 0.1 - 200 kbps
TA Operating Temperature -40 - 85 °C
TSTG Storage Temperature -65 - 150 °C
ESD Electrostatic Discharge Tolerance - - 2000 V

Instructions for SI4401DDY

  1. Power Supply:

    • Ensure the supply voltage ( V_ ) is within the range of 2.1V to 3.6V.
    • Use a stable power source to avoid fluctuations that can affect performance.
  2. Oscillator Configuration:

    • Connect an external crystal oscillator with a frequency between 13.56 MHz and 26 MHz to the XTAL1 and XTAL2 pins.
    • Ensure the oscillator is stable and meets the specified frequency range.
  3. Frequency Selection:

    • Set the desired operating frequency within the range of 300 MHz to 960 MHz using the appropriate register settings.
    • Refer to the datasheet for specific register configurations.
  4. Output Power:

    • Adjust the output power level from -20 dBm to +10 dBm using the PA_LEVEL register.
    • Higher power levels may require additional heat dissipation considerations.
  5. Data Rate:

    • Set the data rate between 0.1 kbps and 200 kbps using the DATA_RATE register.
    • Lower data rates provide better range and reliability but reduce throughput.
  6. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 85°C for optimal performance.
    • Store the device within the temperature range of -65°C to 150°C to ensure long-term reliability.
  7. ESD Protection:

    • Handle the device with care to avoid damage from electrostatic discharge.
    • Use proper ESD protection equipment and practices when handling the device.
  8. Initialization:

    • Follow the initialization sequence outlined in the datasheet to configure the device properly.
    • Use the provided example code or reference designs to simplify the setup process.
  9. Communication Interface:

    • Use the SPI interface to communicate with the device.
    • Ensure the SPI clock speed is within the supported range and that the communication protocol is correctly implemented.
  10. Interrupt Handling:

    • Configure and handle interrupts as needed to manage device events and status updates.
    • Refer to the interrupt register documentation for specific event codes and handling procedures.
(For reference only)

 Inquiry - SI4401DDY