DS1286

Specifications

SKU: 12604279

BUY DS1286 https://www.utsource.net/itm/p/12604279.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.75 5 5.25 V
Supply Current ICC Active (Typical) - 30 - μA
Supply Current ICC Standby (Typical) - 1 - μA
Operating Temperature Toper - -40 - 85 °C
Storage Temperature Tstg - -65 - 150 °C
Output High Voltage VOH IOL = -400μA 2.4 - VCC-0.4 V
Output Low Voltage VOL IOH = 1.6mA 0 - 0.4 V
Input Leakage Current IIH VI = VCC -1 - 1 μA
Input Leakage Current IIL VI = 0V -1 - 1 μA
Write Cycle Time tWC - 10 - - ms
Read Access Time tRC - 0 250 550 ns
Data Hold Time tDH - 0 - 50 ns
Address Setup Time tAS - 0 25 100 ns
Address Hold Time tAH - 0 - 50 ns
Chip Select Pulse Width tCS - 50 - - ns

Instructions for Using the DS1286

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 4.75V to 5.25V.
    • The device operates with a typical active current of 30μA and a standby current of 1μA.
  2. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -65°C to 150°C.
  3. Input/Output Levels:

    • Output high voltage (VOH) should be at least 2.4V when the output current (IOL) is -400μA.
    • Output low voltage (VOL) should not exceed 0.4V when the output current (IOH) is 1.6mA.
    • Input leakage current (IIH and IIL) should be within ±1μA.
  4. Timing Parameters:

    • The write cycle time (tWC) is 10ms.
    • The read access time (tRC) is between 250ns and 550ns.
    • The data hold time (tDH) is 50ns.
    • The address setup time (tAS) is between 25ns and 100ns.
    • The address hold time (tAH) is 50ns.
    • The chip select pulse width (tCS) is 50ns.
  5. Usage:

    • Connect the VCC pin to the power supply and GND to ground.
    • Use the chip select (CS), read/write (R/W), and enable (OE) pins to control data access.
    • Ensure that the address lines (A0-A13) are correctly set to access the desired memory location.
    • Data input/output (D0-D7) lines should be connected to the system bus for data transfer.
  6. Programming:

    • To write data, set the R/W line low and the CS line low, then provide the address and data.
    • To read data, set the R/W line high and the CS line low, then provide the address and read the data from the D0-D7 lines.
  7. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Store the device in a controlled environment within the specified temperature range.
  8. Troubleshooting:

    • If the device does not respond, check the power supply and connections.
    • Verify that the timing parameters are met.
    • Ensure that the address and data lines are correctly configured.

By following these instructions, you can effectively use the DS1286 in your application.

(For reference only)