Share:


IRGP4640D-E

Specifications

SKU: 12604479

BUY IRGP4640D-E https://www.utsource.net/itm/p/12604479.html

Parameter Symbol Test Conditions Min Typ Max Unit
Collector-Emitter Voltage VCEO IC = 0, TJ = 25°C - 600 - V
Gate-Emitter Voltage VGE IC = 0, TJ = 25°C -15 0 15 V
Continuous Collector Current IC TC = 25°C - 16 - A
Continuous Collector Current (TC = 75°C) IC(TC = 75°C) TC = 75°C - 12 - A
Pulse Collector Current IC(pulse) TC = 25°C, tp = 10 μs, duty cycle = 1% - 32 - A
Total Power Dissipation PT TC = 25°C - 180 - W
Junction to Case Thermal Resistance RθJC - - 0.62 - °C/W
Junction to Ambient Thermal Resistance RθJA - - 40 - °C/W
Turn-On Delay Time td(on) VGE = 15V, IC = 10A, RG = 1Ω - 90 - ns
Rise Time tr VGE = 15V, IC = 10A, RG = 1Ω - 60 - ns
Turn-Off Delay Time td(off) VGE = -15V, IC = 10A, RG = 1Ω - 120 - ns
Fall Time tf VGE = -15V, IC = 10A, RG = 1Ω - 90 - ns

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to maintain junction temperature within safe limits.
    • Handle with care to avoid damage to the pins and the die.
  2. Biasing:

    • Apply the appropriate gate-emitter voltage (VGE) to control the transistor.
    • Ensure the gate resistor (RG) is correctly chosen to limit gate current and reduce switching losses.
  3. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it does not exceed the maximum rating.
    • Use thermal paste between the transistor and the heatsink to improve thermal conductivity.
  4. Current and Voltage Ratings:

    • Do not exceed the maximum collector-emitter voltage (VCEO) or continuous collector current (IC).
    • For pulse applications, ensure the pulse duration and duty cycle are within specified limits.
  5. Switching Characteristics:

    • Optimize the turn-on and turn-off times by adjusting the gate resistance (RG).
    • Be aware of the turn-on delay time (td(on)), rise time (tr), turn-off delay time (td(off)), and fall time (tf) to minimize switching losses.
  6. Storage and Operation:

    • Store in a dry, cool environment to prevent moisture damage.
    • Operate within the specified temperature range to ensure reliable performance.
  7. Testing:

    • Use the test conditions provided in the parameter table for accurate measurements.
    • Regularly check the device parameters to ensure they remain within the specified limits.
  8. Safety:

    • Follow all safety guidelines when handling high voltages and currents.
    • Use appropriate protective equipment and follow best practices for electrical safety.
(For reference only)

 Inquiry - IRGP4640D-E