DS2438Z

Specifications

SKU: 12604645

BUY DS2438Z https://www.utsource.net/itm/p/12604645.html

Parameter Symbol Min Typical Max Unit Notes
Operating Voltage VDD 2.8 - 5.25 V
Standby Current IDD - 1.0 1.5 μA
Active Current IDD - 300 500 μA
Conversion Time (12-bit) tCONV - 750 - ms
Temperature Range T -40 - 85 °C
1-Wire Bus Speed fBUS - 16.3 - kHz
Supply Current (Active) ISUP - 1.0 1.5 mA
Supply Current (Idle) ISUP - 1.0 1.5 μA
Output Voltage Range VOUT 0 - VDD V

Instructions for Using DS2438Z

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 2.8V to 5.25V.
    • The device can operate with a wide range of supply currents, but typical values should be considered for optimal performance.
  2. 1-Wire Communication:

    • Connect the 1-Wire bus to the appropriate pin on the DS2438Z.
    • Use a pull-up resistor (typically 4.7kΩ) on the 1-Wire bus to ensure proper communication.
    • The 1-Wire bus speed should not exceed 16.3kHz for reliable operation.
  3. Temperature Sensing:

    • The DS2438Z can measure temperatures from -40°C to 85°C.
    • Use the appropriate commands to initiate temperature conversion and read the results.
  4. Voltage Measurement:

    • The device can measure voltages from 0V to VDD.
    • Use the appropriate commands to initiate voltage conversion and read the results.
  5. Current Measurement:

    • The DS2438Z can measure current by monitoring the voltage drop across a known resistance.
    • Use the appropriate commands to initiate current conversion and read the results.
  6. Standby Mode:

    • To minimize power consumption, place the device in standby mode when not actively measuring.
    • The standby current is typically 1.0μA.
  7. Active Mode:

    • When performing measurements, the active current can range from 300μA to 500μA.
    • Ensure the power supply can handle this current draw.
  8. Conversion Time:

    • The typical conversion time for a 12-bit measurement is 750ms.
    • Allow sufficient time for the conversion to complete before reading the results.
  9. Programming:

    • Refer to the datasheet for specific command codes and programming sequences.
    • Use a 1-Wire master device (e.g., microcontroller) to send commands and read data from the DS2438Z.
  10. Handling and Storage:

    • Store the device in a dry environment to prevent damage.
    • Handle with care to avoid static discharge, which can damage the device.

For detailed command sequences and additional information, refer to the DS2438Z datasheet provided by the manufacturer.

(For reference only)

 Inquiry - DS2438Z