Specifications
SKU: 12606472
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 60 | V | Operating input voltage range |
Output Voltage | VOUT | - | 30 | - | V | Regulated output voltage |
Output Current | IOUT | - | 1.5 | 3 | A | Continuous output current |
Efficiency | η | - | 92 | - | % | Typical efficiency at nominal load |
Switching Frequency | fSW | - | 300 | - | kHz | Switching frequency |
Quiescent Current | IQ | - | 0.5 | - | mA | Quiescent current |
Dropout Voltage | VDROPOUT | - | 0.5 | - | V | Dropout voltage |
Operating Temperature | TOPR | -40 | - | 125 | °C | Operating temperature range |
Storage Temperature | TSTG | -55 | - | 150 | °C | Storage temperature range |
Thermal Resistance | RθJA | - | 40 | - | °C/W | Junction-to-ambient thermal resistance |
Instructions:
Input Connection:
- Connect the input voltage (VIN) to the input terminal.
- Ensure the input voltage is within the specified range (4.5V to 60V).
Output Connection:
- Connect the output terminals to the load.
- The output voltage (VOUT) is regulated to 30V.
Load Regulation:
- The device can provide a continuous output current up to 3A.
- For optimal performance, keep the load within the recommended range.
Thermal Management:
- Ensure adequate heat dissipation to maintain the junction temperature within safe limits.
- Use a heatsink if necessary, especially under high load conditions.
Efficiency:
- The device operates with a typical efficiency of 92% at nominal load conditions.
- Monitor the efficiency to ensure optimal performance.
Operating and Storage Temperature:
- Operate the device within the temperature range of -40°C to 125°C.
- Store the device within the temperature range of -55°C to 150°C.
** Dropout Voltage:**
- The dropout voltage is 0.5V. Ensure that the input voltage is at least 0.5V higher than the output voltage for proper regulation.
Quiescent Current:
- The quiescent current is typically 0.5mA. This is the current consumed by the device when it is active but not driving a load.
Switching Frequency:
- The switching frequency is set to 300kHz. This helps in reducing the size of external components like inductors and capacitors.
Safety Precautions:
- Always follow standard safety procedures when handling electronic components.
- Avoid short circuits and overvoltage conditions to prevent damage to the device.
Inquiry - FF60UP30DN