Specifications
SKU: 12607368
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VIN | 2.5 | - | 5.5 | V | Operating input voltage range |
Output Voltage | VOUT | - | 3.3 | - | V | Fixed output voltage |
Output Current | IOUT | - | 150 | 200 | mA | Maximum continuous output current |
Quiescent Current | IQ | - | 20 | 30 | μA | Quiescent current at no load |
Dropout Voltage | VDROP | - | 200 | 300 | mV | Voltage difference between VIN and VOUT at max IOUT |
Load Regulation | - | - | 1 | 2 | % | Change in VOUT with load |
Line Regulation | - | - | 0.1 | 0.5 | %/V | Change in VOUT with VIN |
PSRR (1 kHz) | - | - | 60 | 70 | dB | Power supply rejection ratio |
Operating Temp. | TOP | -40 | - | 85 | °C | Operating temperature range |
Storage Temp. | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions for Using ACT74
Power Supply Connection:
- Connect the input voltage (VIN) to the VIN pin.
- Ensure the input voltage is within the specified range (2.5V to 5.5V).
Output Connection:
- Connect the output voltage (VOUT) to the VOUT pin.
- The output voltage is fixed at 3.3V.
Ground Connection:
- Connect the ground (GND) to both the VIN and VOUT pins to ensure proper operation.
Capacitors:
- Place a 1μF ceramic capacitor close to the VIN pin to filter out noise and stabilize the input voltage.
- Place a 1μF ceramic capacitor close to the VOUT pin to stabilize the output voltage and improve transient response.
Thermal Considerations:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- Use a heatsink if necessary to keep the device within the operating temperature range.
Load Regulation:
- The output voltage may vary slightly with changes in load. The typical load regulation is 1%.
Line Regulation:
- The output voltage may vary slightly with changes in input voltage. The typical line regulation is 0.1% per volt.
Power Supply Rejection Ratio (PSRR):
- The device has a good ability to reject ripple from the input voltage, with a typical PSRR of 60 dB at 1 kHz.
Operating Temperature:
- The device is designed to operate within the temperature range of -40°C to 85°C.
Storage Temperature:
- Store the device in a dry environment within the temperature range of -65°C to 150°C.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
By following these instructions, you can ensure optimal performance and reliability of the ACT74 regulator.
(For reference only)Inquiry - ACT74