Specifications
SKU: 12607655
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 1.6 | - | 5.5 | V | Operating voltage range |
Supply Current (Quiescent) | IQ | - | 0.2 | - | μA | Quiescent current at no load |
Output Voltage | VOUT | - | 3.3 | - | V | Regulated output voltage |
Output Current | IOUT | - | 500 | - | mA | Maximum continuous output current |
Dropout Voltage | VDROPOUT | - | 0.3 | - | V | Voltage difference between input and output |
Load Regulation | - | - | 0.5 | - | % | Change in output voltage with load |
Line Regulation | - | - | 0.1 | - | % | Change in output voltage with input voltage |
Ripple Rejection | - | - | 60 | - | dB | Attenuation of input ripple at the output |
Operating Temperature | Toper | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | Tstg | -65 | - | 150 | °C | Temperature range for storage |
Package Type | - | - | - | - | SOT-23 | Package type |
Instructions for Use:
Power Supply Connection:
- Connect the VDD pin to the positive supply voltage.
- Connect the GND pin to the common ground.
Output Connection:
- Connect the VOUT pin to the load or circuit requiring the regulated output voltage.
Capacitors:
- Place a 1 μF ceramic capacitor between VDD and GND as close to the regulator as possible to ensure stability.
- Place a 1 μF ceramic capacitor between VOUT and GND to filter the output and reduce ripple.
Thermal Management:
- Ensure adequate heat dissipation if operating at high output currents, especially in high ambient temperatures.
- Consider using a heatsink if necessary.
Operating Conditions:
- Ensure the input voltage is within the specified range (1.6V to 5.5V).
- Do not exceed the maximum output current of 500 mA continuously.
- Operate within the specified temperature range (-40°C to 85°C).
Storage:
- Store the device in a dry environment within the storage temperature range (-65°C to 150°C).
Handling:
- Handle the device with care to avoid damage to the pins and package.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Test the output voltage and current to ensure the regulator is functioning correctly.
- Verify the ripple rejection and load regulation to meet the required specifications.