Share:


74HC193AP

Specifications

SKU: 12607720

BUY 74HC193AP https://www.utsource.net/itm/p/12607720.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.0 - 6.0 V
Input Low Voltage VIL VCC = 4.5V to 5.5V 0.8 - - V
Input High Voltage VIH VCC = 4.5V to 5.5V - - 2.0 V
Output Low Voltage VOL IOL = 4mA, VCC = 4.5V to 5.5V 0.1 - - V
Output High Voltage VOH IOH = -0.4mA, VCC = 4.5V to 5.5V - - 4.5 V
Propagation Delay Time tpd VCC = 4.5V to 5.5V, TA = 25°C - 25 - ns
Power Dissipation PD Continuous - - 100 mW
Operating Temperature Range TA - -40 - 85 °C
Storage Temperature Range TSTG - -65 - 150 °C

Instructions for Using 74HC193AP:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
    • Connect the ground (GND) pin to a stable reference ground.
  2. Input Signals:

    • Input signals should be within the specified input voltage levels (VIL and VIH).
    • Avoid exceeding the maximum input voltage to prevent damage to the device.
  3. Output Signals:

    • The output voltages (VOL and VOH) are designed to meet the specified levels under the given conditions.
    • Ensure that the load connected to the outputs does not exceed the maximum current ratings.
  4. Propagation Delay:

    • The propagation delay time (tpd) is crucial for timing considerations in your circuit. It is typically around 25ns at room temperature and standard supply voltage.
  5. Temperature Considerations:

    • The operating temperature range (TA) is from -40°C to 85°C. Ensure the device is used within this range to avoid performance degradation or failure.
    • The storage temperature range (TSTG) is from -65°C to 150°C, which is important for handling and storage conditions.
  6. Power Dissipation:

    • The maximum power dissipation (PD) is 100mW. Ensure proper heat dissipation if the device is expected to operate near this limit.
  7. Handling and Storage:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Store the device in a dry and cool environment to prevent moisture damage.

By following these guidelines, you can ensure reliable operation of the 74HC193AP in your circuits.

(For reference only)

 Inquiry - 74HC193AP