Specifications
SKU: 12607720
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 2.0 | - | 6.0 | V |
Input Low Voltage | VIL | VCC = 4.5V to 5.5V | 0.8 | - | - | V |
Input High Voltage | VIH | VCC = 4.5V to 5.5V | - | - | 2.0 | V |
Output Low Voltage | VOL | IOL = 4mA, VCC = 4.5V to 5.5V | 0.1 | - | - | V |
Output High Voltage | VOH | IOH = -0.4mA, VCC = 4.5V to 5.5V | - | - | 4.5 | V |
Propagation Delay Time | tpd | VCC = 4.5V to 5.5V, TA = 25°C | - | 25 | - | ns |
Power Dissipation | PD | Continuous | - | - | 100 | mW |
Operating Temperature Range | TA | - | -40 | - | 85 | °C |
Storage Temperature Range | TSTG | - | -65 | - | 150 | °C |
Instructions for Using 74HC193AP:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
- Connect the ground (GND) pin to a stable reference ground.
Input Signals:
- Input signals should be within the specified input voltage levels (VIL and VIH).
- Avoid exceeding the maximum input voltage to prevent damage to the device.
Output Signals:
- The output voltages (VOL and VOH) are designed to meet the specified levels under the given conditions.
- Ensure that the load connected to the outputs does not exceed the maximum current ratings.
Propagation Delay:
- The propagation delay time (tpd) is crucial for timing considerations in your circuit. It is typically around 25ns at room temperature and standard supply voltage.
Temperature Considerations:
- The operating temperature range (TA) is from -40°C to 85°C. Ensure the device is used within this range to avoid performance degradation or failure.
- The storage temperature range (TSTG) is from -65°C to 150°C, which is important for handling and storage conditions.
Power Dissipation:
- The maximum power dissipation (PD) is 100mW. Ensure proper heat dissipation if the device is expected to operate near this limit.
Handling and Storage:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Store the device in a dry and cool environment to prevent moisture damage.
By following these guidelines, you can ensure reliable operation of the 74HC193AP in your circuits.