Specifications
SKU: 12607795
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 2.7 | - | 5.5 | V | Operating supply voltage range |
Supply Current | IDD | - | 300 | - | μA | Quiescent current at VDD = 5V, TA = 25°C |
Input Voltage Range | VIN | 0 | - | VDD | V | Valid input voltage range for digital inputs |
Output Voltage (High) | VOH | - | VDD-0.4 | VDD-0.1 | V | Output high voltage at IOH = 1mA, VDD = 5V, TA = 25°C |
Output Voltage (Low) | VOL | 0.1 | 0.4 | - | V | Output low voltage at IOL = 1mA, VDD = 5V, TA = 25°C |
Propagation Delay Time | tpd | 10 | 15 | 20 | ns | Propagation delay time from input to output at VDD = 5V, TA = 25°C |
Operating Temperature | TA | -40 | - | 85 | °C | Ambient operating temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions for TCDT1124
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- The quiescent current (IDD) should not exceed 300μA at VDD = 5V and TA = 25°C.
Input Signals:
- Digital input voltages (VIN) must be within the range of 0V to VDD.
- Ensure that the input signals are clean and stable to avoid erroneous operation.
Output Signals:
- The output high voltage (VOH) will be at least VDD - 0.4V and can reach up to VDD - 0.1V when sourcing 1mA.
- The output low voltage (VOL) will be between 0.1V and 0.4V when sinking 1mA.
Timing:
- The propagation delay time (tpd) from input to output is typically 15ns, with a minimum of 10ns and a maximum of 20ns at VDD = 5V and TA = 25°C.
Temperature Considerations:
- The device is designed to operate in ambient temperatures ranging from -40°C to 85°C.
- Store the device in temperatures ranging from -65°C to 150°C.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Use proper ESD protection equipment when handling the device.
Mounting:
- Follow the recommended soldering profile to ensure reliable mounting on the PCB.
- Avoid excessive thermal stress during soldering.
Testing:
- Perform initial testing at room temperature (25°C) to verify functionality.
- Conduct additional tests at the extreme ends of the operating temperature range to ensure robust performance.
Troubleshooting:
- If the device does not function as expected, check the power supply, input signals, and connections.
- Verify that the device is not operating outside its specified temperature range.
For detailed specifications and additional information, refer to the datasheet provided by the manufacturer.