Share:


ERA85-009

Specifications

SKU: 12608067

BUY ERA85-009 https://www.utsource.net/itm/p/12608067.html

Parameter Description Value
Part Number Full part number ERA85-009
Type Type of device RF Amplifier Module
Frequency Range Operating frequency range 700 MHz to 3000 MHz
Gain Gain at typical operating conditions 22 dB
Noise Figure Noise figure at typical operating conditions 4.5 dB
Output Power Output power at 1 dB compression point (P1dB) 27 dBm
Input VSWR Voltage Standing Wave Ratio at input 2.0:1
Output VSWR Voltage Standing Wave Ratio at output 2.0:1
Supply Voltage Recommended supply voltage +12 VDC
Supply Current Typical supply current 150 mA
Operating Temperature Temperature range for operation -40°C to +85°C
Storage Temperature Temperature range for storage -55°C to +125°C
Package Type Type of package SMT (Surface Mount Technology)
Dimensions Physical dimensions (L x W x H) 15.24 mm x 10.16 mm x 3.05 mm
Weight Weight of the module 1.5 g

Instructions for Use

  1. Power Supply:

    • Connect the +12 VDC supply to the designated pins on the module.
    • Ensure the supply voltage is stable and within the specified range to avoid damage.
  2. Signal Connections:

    • Connect the input signal to the input port and the output signal to the output port.
    • Use appropriate RF connectors and cables to minimize signal loss and ensure good impedance matching.
  3. Heat Management:

    • The module should be mounted on a heat sink or a PCB with adequate thermal management to dissipate heat effectively.
    • Ensure the operating temperature does not exceed the specified range to prevent thermal damage.
  4. Handling:

    • Handle the module with care to avoid physical damage.
    • Use ESD (Electrostatic Discharge) protection measures when handling the module to prevent damage from static electricity.
  5. Testing:

    • Before final installation, test the module using a signal generator and spectrum analyzer to verify performance parameters such as gain, noise figure, and output power.
    • Refer to the datasheet for detailed testing procedures and recommended test setups.
  6. Storage:

    • Store the module in a dry, cool place away from direct sunlight and extreme temperatures.
    • Keep the module in its original packaging until ready for use to protect it from environmental factors.
  7. Compliance:

    • Ensure that the module complies with all relevant regulatory standards and certifications for your application and region.
(For reference only)

 Inquiry - ERA85-009