Share:


SPW20N60S5

Specifications

SKU: 12608379

BUY SPW20N60S5 https://www.utsource.net/itm/p/12608379.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS - 600 - V
Gate-Source Voltage VGS -15 0 20 V
Continuous Drain Current ID - 20 - A @ TC = 25°C
Pulse Drain Current IDpeak - 80 - A tp = 10 μs, Duty Cycle = 1%
Power Dissipation PTOT - - 320 W @ TC = 25°C
Junction Temperature TJ - - 175 °C
Storage Temperature TSTG -55 - 150 °C
Thermal Resistance (Junction to Case) RθJC - - 0.45 °C/W
Total Gate Charge QG - 98 - nC @ VGS = 15V, ID = 10A
Input Capacitance Ciss - 1900 - pF @ VDS = 400V, f = 1 MHz
Output Capacitance Coss - 360 - pF @ VDS = 400V, f = 1 MHz
Reverse Transfer Capacitance Crss - 340 - pF @ VDS = 400V, f = 1 MHz
Turn-on Delay Time td(on) - 53 - ns @ VGS = 15V, ID = 10A, Rg = 1Ω
Rise Time tr - 58 - ns @ VGS = 15V, ID = 10A, Rg = 1Ω
Turn-off Delay Time td(off) - 34 - ns @ VGS = 15V, ID = 10A, Rg = 1Ω
Fall Time tf - 57 - ns @ VGS = 15V, ID = 10A, Rg = 1Ω

Instructions:

  1. Handling and Storage:

    • Store the device in a dry, cool place away from direct sunlight.
    • Handle with care to avoid damage to the leads and body.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the specified limits.
    • Use a thermal interface material (TIM) between the device and the heatsink for better thermal performance.
  3. Electrical Connections:

    • Apply a gate-source voltage (VGS) within the specified range to ensure reliable operation.
    • Avoid exceeding the maximum drain-source voltage (VDS) to prevent breakdown.
  4. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it does not exceed 175°C.
    • Use the thermal resistance (RθJC) to calculate the required heatsink size.
  5. Operational Considerations:

    • For high-frequency applications, consider the total gate charge (QG) and switching times (td(on), tr, td(off), tf) to optimize performance.
    • Ensure the input capacitance (Ciss) and output capacitance (Coss) are accounted for in circuit design to minimize parasitic effects.
  6. Safety Precautions:

    • Always use appropriate safety measures when handling high-voltage and high-current circuits.
    • Follow all relevant electrical and mechanical standards and regulations.
(For reference only)