Specifications
SKU: 12608555
Below is the parameter table and instructions for the A6063H component.
Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | 5.0 | 5.5 | V | |
Output Current (High Level) | Ioh | - | 20 | 40 | mA | Vcc = 5V |
Output Current (Low Level) | Iol | 20 | 40 | - | mA | Vcc = 5V |
Input Voltage (High Level) | VIH | 3.0 | - | 5.0 | V | |
Input Voltage (Low Level) | VIL | 0.0 | - | 1.5 | V | |
Propagation Delay Time (High to Low) | tPLH | - | 15 | - | ns | Vcc = 5V, RL = 150Ω |
Propagation Delay Time (Low to High) | tPHL | - | 15 | - | ns | Vcc = 5V, RL = 150Ω |
Power Consumption | Pd | - | 100 | - | mW | Vcc = 5V |
Operating Temperature Range | Ta | -40 | - | 85 | °C | |
Storage Temperature Range | Tstg | -65 | - | 150 | °C |
Instructions
Supply Voltage:
- Ensure the supply voltage (Vcc) is within the range of 4.5V to 5.5V.
- The typical operating voltage is 5.0V.
Output Current:
- The output current when high (Ioh) can be up to 40mA.
- The output current when low (Iol) can be up to 40mA.
- Ensure the load resistance (RL) is appropriate to avoid exceeding these limits.
Input Voltage:
- The input voltage for a high level (VIH) should be between 3.0V and 5.0V.
- The input voltage for a low level (VIL) should be between 0.0V and 1.5V.
Propagation Delay:
- The propagation delay time from high to low (tPLH) and from low to high (tPHL) is typically 15ns.
- These values are measured with Vcc = 5V and a load resistance of 150Ω.
Power Consumption:
- The power consumption (Pd) is typically 100mW at Vcc = 5V.
Operating Temperature:
- The operating temperature range (Ta) is from -40°C to 85°C.
- Ensure the component is used within this range to avoid damage.
Storage Temperature:
- The storage temperature range (Tstg) is from -65°C to 150°C.
- Store the component in a dry and cool place to prevent damage.
Handling:
- Handle the component with care to avoid static discharge.
- Use appropriate ESD protection when handling the component.
Mounting:
- Follow the recommended soldering profile to ensure proper mounting.
- Avoid excessive heat during soldering to prevent damage to the component.
Testing:
- Test the component under controlled conditions to verify its performance.
- Use a multimeter or an oscilloscope to measure the parameters as needed.
By following these instructions, you can ensure the A6063H operates reliably and efficiently in your application.