Specifications
SKU: 12611093
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Forward Current | IF | - | 50 | 100 | mA |
Reverse Voltage | VR | - | - | 5 | V |
Forward Voltage | VF | 1.1 | 1.3 | 1.5 | V |
Peak Wavelength | λp | 850 | - | 870 | nm |
Radiant Intensity | Iv | 1.5 | 3.0 | 5.0 | mW/sr |
Viewing Angle (1/2 intensity) | θ1/2 | 10 | - | 15 | ° |
Operating Temperature | Toper | -40 | - | 100 | °C |
Storage Temperature | Tstg | -40 | - | 125 | °C |
Instructions for Use:
Mounting:
- Ensure that the component is mounted on a PCB with proper thermal management to prevent overheating.
- Use appropriate soldering techniques to avoid damage from excessive heat.
Electrical Connections:
- Connect the anode (A) and cathode (K) terminals correctly to avoid reverse bias, which can damage the component.
- Use current-limiting resistors to ensure the forward current (IF) does not exceed the maximum rating.
Thermal Management:
- Ensure adequate cooling if the component is operated at high currents or in high ambient temperatures.
- Consider using a heatsink if necessary.
Environmental Conditions:
- Operate the component within the specified temperature ranges to ensure reliable performance.
- Store the component in a dry environment to prevent moisture damage.
Handling:
- Handle the component with care to avoid mechanical damage.
- Use ESD (Electrostatic Discharge) protection when handling to prevent damage from static electricity.
Testing:
- Use a suitable power supply and measurement equipment to test the component.
- Verify the forward voltage (VF) and radiant intensity (Iv) to ensure the component is functioning correctly.
Compliance:
- Ensure that the use of the component complies with all relevant safety and regulatory standards.
Inquiry - SFH6286-3