Share:


60T65PES

Specifications

SKU: 12611380

BUY 60T65PES https://www.utsource.net/itm/p/12611380.html

Parameter Symbol Min Typ Max Unit
Rated Voltage VRMS - 650 - V
Peak Repetitive Reverse Voltage VRRM - 900 - V
Continuous Forward Current (Tc = 25°C) IF - 60 - A
Continuous Forward Current (Tc = 75°C) IF - 45 - A
Non-repetitive Peak Surge Current (8.3/400μs) IFSM - 300 - A
Junction Temperature TJ - - 175 °C
Storage Temperature TSTG -55 - 150 °C
Operating Temperature TA -55 - 150 °C
Forward Voltage at Rated Current VF - 1.1 - V
Reverse Recovery Time trr - 35 - ns
Reverse Recovery Charge Qrr - 120 - nC

Instructions for Use:

  1. Mounting and Handling:

    • Handle the device with care to avoid mechanical stress.
    • Ensure proper heat sinking to maintain the junction temperature within the specified limits.
  2. Electrical Connections:

    • Connect the device according to the circuit diagram provided.
    • Use appropriate wire gauges to handle the rated current without excessive resistance.
  3. Thermal Management:

    • Ensure adequate cooling to keep the junction temperature below 175°C.
    • Consider forced air cooling or heat sinks for high-power applications.
  4. Surge Current:

    • The device can handle non-repetitive peak surge currents up to 300A for 8.3/400μs pulses.
    • Ensure that the surge current does not exceed this limit to prevent damage.
  5. Storage and Operating Temperature:

    • Store the device in a dry environment between -55°C and 150°C.
    • Operate the device within the same temperature range to ensure reliable performance.
  6. Reverse Recovery:

    • Be aware of the reverse recovery time (35ns) and charge (120nC) when designing the circuit to avoid excessive voltage spikes during switching.
  7. Forward Voltage:

    • The forward voltage drop is typically 1.1V at the rated current. Design the power supply and circuit to accommodate this voltage drop.
  8. Safety Precautions:

    • Always follow safety guidelines and use protective equipment when handling high-voltage components.
    • Ensure proper insulation and grounding to prevent electrical hazards.
(For reference only)

 Inquiry - 60T65PES