Specifications
SKU: 12611380
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Rated Voltage | VRMS | - | 650 | - | V |
Peak Repetitive Reverse Voltage | VRRM | - | 900 | - | V |
Continuous Forward Current (Tc = 25°C) | IF | - | 60 | - | A |
Continuous Forward Current (Tc = 75°C) | IF | - | 45 | - | A |
Non-repetitive Peak Surge Current (8.3/400μs) | IFSM | - | 300 | - | A |
Junction Temperature | TJ | - | - | 175 | °C |
Storage Temperature | TSTG | -55 | - | 150 | °C |
Operating Temperature | TA | -55 | - | 150 | °C |
Forward Voltage at Rated Current | VF | - | 1.1 | - | V |
Reverse Recovery Time | trr | - | 35 | - | ns |
Reverse Recovery Charge | Qrr | - | 120 | - | nC |
Instructions for Use:
Mounting and Handling:
- Handle the device with care to avoid mechanical stress.
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
Electrical Connections:
- Connect the device according to the circuit diagram provided.
- Use appropriate wire gauges to handle the rated current without excessive resistance.
Thermal Management:
- Ensure adequate cooling to keep the junction temperature below 175°C.
- Consider forced air cooling or heat sinks for high-power applications.
Surge Current:
- The device can handle non-repetitive peak surge currents up to 300A for 8.3/400μs pulses.
- Ensure that the surge current does not exceed this limit to prevent damage.
Storage and Operating Temperature:
- Store the device in a dry environment between -55°C and 150°C.
- Operate the device within the same temperature range to ensure reliable performance.
Reverse Recovery:
- Be aware of the reverse recovery time (35ns) and charge (120nC) when designing the circuit to avoid excessive voltage spikes during switching.
Forward Voltage:
- The forward voltage drop is typically 1.1V at the rated current. Design the power supply and circuit to accommodate this voltage drop.
Safety Precautions:
- Always follow safety guidelines and use protective equipment when handling high-voltage components.
- Ensure proper insulation and grounding to prevent electrical hazards.
Inquiry - 60T65PES