Specifications
SKU: 12611384
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 12 | 15 | 18 | V | Operating voltage range |
Quiescent Current | Iq | - | 10 | - | mA | Current consumption at no load |
Output Power | Po | - | 10 | - | W | Maximum output power into 8Ω load |
Total Harmonic Distortion | THD | - | 0.1 | - | % | At 1kHz, 1W into 8Ω |
Signal-to-Noise Ratio | SNR | - | 90 | - | dB | A-weighted, referenced to 1W into 8Ω |
Frequency Response | FR | 20 | - | 20000 | Hz | Flat within ±1dB |
Thermal Shutdown Temperature | TSD | - | 150 | - | °C | Temperature at which the device shuts down to prevent damage |
Storage Temperature | Tstg | -40 | - | 125 | °C | Temperature range for storage and non-operating conditions |
Operating Temperature | Topr | -25 | - | 85 | °C | Temperature range for normal operation |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 12V to 18V.
- Use a stable power source to avoid fluctuations that could affect performance.
Heat Dissipation:
- Mount the TDA4601 on a heatsink if operating at high power levels or in high ambient temperatures.
- Ensure adequate ventilation to prevent the device from exceeding the thermal shutdown temperature (150°C).
Input Signal:
- Apply the input signal to the designated input pins.
- Keep the input signal within the recommended levels to avoid distortion and potential damage.
Output Connection:
- Connect the speaker to the output terminals, ensuring the impedance matches the specified load (8Ω).
- Use appropriate wiring to minimize interference and ensure safe operation.
Protection:
- The device includes thermal protection to prevent damage from overheating.
- Do not short-circuit the output to ground or other outputs.
Storage and Handling:
- Store the device in a dry environment within the specified storage temperature range (-40°C to 125°C).
- Handle with care to avoid mechanical damage and static discharge.
Testing:
- Before final installation, test the device under typical operating conditions to ensure it meets performance specifications.
- Use a signal generator and an oscilloscope to verify the frequency response and distortion levels.
Inquiry - TDA4601