Share:


NDH2412SC

Specifications

SKU: 12611489

BUY NDH2412SC https://www.utsource.net/itm/p/12611489.html

Parameter Description Min Typ Max Unit
Input Voltage (VIN) Operating input voltage range 2.7 - 5.5 V
Output Voltage (VOUT) Fixed output voltage - 3.3 - V
Output Current (IOUT) Continuous output current - 1.2 1.5 A
Quiescent Current (IQ) Supply current in active mode - 100 200 μA
Shutdown Current (ISD) Supply current in shutdown mode - 1 5 μA
Dropout Voltage (VDROP) Difference between VIN and VOUT at IOUT = 1.2A - 200 300 mV
Load Regulation Change in VOUT with load current from 0 to 1.2A - 2 5 mV
Line Regulation Change in VOUT with VIN from 2.7 to 5.5V - 1 3 mV
PSRR (Power Supply Rejection Ratio) Attenuation of ripple from VIN to VOUT at 1kHz - 60 70 dB
Thermal Shutdown Temperature (TSD) Temperature at which the device shuts down - 160 180 °C
Operating Junction Temperature (TJ) Range of operating junction temperature -40 - 125 °C
Storage Temperature (TS) Range of storage temperature -65 - 150 °C

Instructions for Using NDH2412SC:

  1. Input Connection:

    • Connect the input voltage (VIN) to the input pin of the NDH2412SC.
    • Ensure the input voltage is within the specified range of 2.7V to 5.5V.
  2. Output Connection:

    • Connect the output pin to the load or circuit that requires a regulated 3.3V supply.
    • The maximum continuous output current is 1.2A, with a peak of 1.5A.
  3. Ground Connection:

    • Connect the ground (GND) pin to the common ground of the system.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the input pin to filter out high-frequency noise.
    • Place a 1μF ceramic capacitor close to the output pin to stabilize the output voltage.
  5. Shutdown Function:

    • To enable the shutdown function, connect the shutdown (SHDN) pin to GND. This will reduce the supply current to approximately 1-5μA.
    • To activate the regulator, connect the SHDN pin to VIN or leave it floating.
  6. Thermal Considerations:

    • Ensure adequate heat dissipation if the regulator is operating at high output currents or in high ambient temperatures.
    • The thermal shutdown temperature is typically 160°C to 180°C to protect the device from overheating.
  7. Operating Environment:

    • The operating junction temperature range is -40°C to 125°C.
    • The storage temperature range is -65°C to 150°C.
  8. PCB Layout:

    • Use a good PCB layout to minimize parasitic inductance and resistance.
    • Keep the input and output capacitors as close as possible to the regulator pins.
  9. Testing:

    • Before finalizing the design, test the regulator under various load conditions to ensure stable operation and proper regulation.
  10. Compliance:

    • Ensure that the design complies with all relevant safety and regulatory standards for the application.
(For reference only)