SRD-6VDC-SL-A

Specifications

SKU: 12611508

BUY SRD-6VDC-SL-A https://www.utsource.net/itm/p/12611508.html

Parameter Description Value
Model Number Model SRD-6VDC-SL-A
Type Relay Type SPDT
Coil Voltage Operating Voltage (Coil) 6V DC
Coil Current Operating Current (Coil) 90mA
Contact Form Contact Configuration SPDT
Contact Rating Switching Capacity 10A, 250VAC
Insulation Resistance Minimum Insulation Resistance 100MΩ
Dielectric Strength Dielectric Withstand Voltage 1500VAC
Operating Temperature Temperature Range -25°C to 70°C
Storage Temperature Storage Temperature Range -40°C to 85°C
Humidity Relative Humidity 5% to 95%
Dimensions Size (L x W x H) 17.5mm x 12.5mm x 12.5mm
Weight Weight 3g
Life Expectancy Mechanical Life 10 million cycles
Operate Time Operate Time 10ms max
Release Time Release Time 5ms max

Instructions:

  1. Installation:

    • Ensure the relay is installed in a well-ventilated area to prevent overheating.
    • Use appropriate wiring and connectors to connect the relay to your circuit.
  2. Power Supply:

    • Connect the coil terminals to a 6V DC power supply.
    • Ensure the power supply can provide at least 90mA of current to operate the relay.
  3. Control Signals:

    • Apply 6V DC to the coil to energize the relay and switch the contacts.
    • Remove the voltage to de-energize the relay and return the contacts to their default position.
  4. Load Connection:

    • Connect the load to the common (COM) and normally open (NO) or normally closed (NC) terminals as required.
    • Ensure the load does not exceed the contact rating of 10A at 250VAC.
  5. Testing:

    • Test the relay by applying and removing the control voltage to verify proper operation.
    • Check for continuity between the COM and NO/NC terminals when the relay is energized and de-energized.
  6. Maintenance:

    • Regularly inspect the relay for signs of wear or damage.
    • Replace the relay if it fails to operate correctly or if any components are damaged.
  7. Safety:

    • Do not exceed the rated voltage and current limits.
    • Avoid operating the relay in environments with excessive dust, moisture, or corrosive gases.
    • Ensure the relay is properly grounded to prevent electrical hazards.
(For reference only)