Specifications
SKU: 12612077
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage (VDD) | Operating supply voltage range | 1.7 | - | 3.6 | V |
Standby Current (ISB) | Current consumption in standby mode | - | 0.1 | - | μA |
Active Current (IACT) | Current consumption in active mode | - | 3.0 | - | mA |
Input Voltage Range (VIN) | Range of input signal voltage | 0 | - | VDD | V |
Output Voltage Swing (VOUT) | Output voltage swing range | 0 | - | VDD - 0.2 | V |
Input Impedance (ZIN) | Input impedance | - | 10 | - | MΩ |
Bandwidth (BW) | Frequency range over which gain is flat within 3 dB | - | 10 | - | MHz |
Slew Rate (SR) | Maximum rate of change of output voltage | - | 1.5 | - | V/μs |
Power-down Time (tPD) | Time to enter power-down mode | - | 1 | - | μs |
Wake-up Time (tWU) | Time to exit power-down mode | - | 1 | - | μs |
Operating Temperature (Toper) | Temperature range for operation | -40 | - | 85 | °C |
Storage Temperature (Tstg) | Temperature range for storage | -65 | - | 150 | °C |
Instructions for Using AF9592
Power Supply:
- Connect the VDD pin to a stable power supply within the range of 1.7V to 3.6V.
- Ensure the ground (GND) pin is connected to the system ground.
Input Signal:
- Apply the input signal to the VIN pin. The input voltage should be within the range of 0V to VDD.
- The input impedance is 10MΩ, so ensure the source impedance is compatible to avoid loading issues.
Output Signal:
- The output signal will be available on the VOUT pin. The output voltage swing is from 0V to VDD - 0.2V.
- Ensure the load impedance is appropriate for the desired output level.
Power Management:
- To enter power-down mode, set the power-down control pin (PD) to a high state.
- To wake up from power-down mode, set the PD pin to a low state.
- The power-down time (tPD) is approximately 1μs, and the wake-up time (tWU) is also approximately 1μs.
Temperature Considerations:
- The device operates reliably within the temperature range of -40°C to 85°C.
- Store the device in a temperature range of -65°C to 150°C to ensure long-term reliability.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store the device in a dry, cool place to prevent moisture-related issues.
Testing and Verification:
- Before finalizing the design, perform thorough testing under various operating conditions to ensure the device meets the required specifications.
- Use a multimeter or oscilloscope to verify the input and output signals, and check the current consumption in both active and standby modes.
Inquiry - AF9592