Parameter Symbol Min Typ Max Unit Description
Input Voltage VI 2.7 - 5.5 V Operating voltage range
Output Voltage VO - 3.3 - V Regulated output voltage
Output Current IO - 300 - mA Maximum continuous output current
Quiescent Current IQ - 1.5 - μA Typical quiescent current at no load
Dropout Voltage VDO - 200 - mV Typical dropout voltage at IO = 300 mA
Load Regulation - - 1 - % Change in output voltage with load (0 to 300 mA)
Line Regulation - - 0.1 - %/V Change in output voltage with input voltage (2.7 to 5.5 V)
Ripple Rejection - - 60 - dB Attenuation of input ripple at 1 kHz
Operating Temperature TA -40 - 85 °C Ambient temperature range
Storage Temperature TSTG -55 - 150 °C Temperature range for storage

Instructions for Use:

  1. Power Supply:

    • Ensure the input voltage is within the specified range (2.7 V to 5.5 V).
    • Connect the input capacitor (1 μF ceramic) close to the input pin to stabilize the input voltage.
  2. Output Configuration:

    • The output voltage is fixed at 3.3 V. No external resistors are required for voltage adjustment.
    • Connect an output capacitor (1 μF ceramic) close to the output pin to filter the output and ensure stability.
  3. Thermal Management:

    • The device is designed to operate efficiently, but for high current applications, ensure adequate heat dissipation.
    • Use a heatsink if the ambient temperature exceeds 85°C or if the device is operating near its maximum current limit.
  4. Protection:

    • The STD03NY includes internal short-circuit and thermal shutdown protection.
    • Do not exceed the maximum output current of 300 mA to avoid overheating and potential damage.
  5. PCB Layout:

    • Keep the PCB traces short and wide to minimize resistance and inductance.
    • Ensure proper grounding and use a ground plane to reduce noise and improve performance.
  6. Handling:

    • Handle the device with care to avoid static damage.
    • Follow ESD (Electrostatic Discharge) precautions during assembly and handling.
  7. Testing:

    • Before finalizing the design, test the circuit under various conditions to ensure it meets the required specifications.
    • Verify the output voltage, ripple rejection, and load regulation to confirm proper operation.
(For reference only)